I. Air Compressor
1. Explosion-proof motor with ExdIIBt4 explosion-proof rating and IP55 protection level.
2. Motor includes a built-in heater (heating method: stops heating when the motor is running; heats when the motor is stopped).
3. Automatic start/stop operation (PLC-controlled): supports switch control for remote start/stop operation.
4. Equipped with an RS485 communication interface.
5. Direct-drive transmission.
6. Electrical control panel is made of stainless steel with IP56 protection and ExdIIBt6 explosion-proof rating.
7. All electrical components except the motor have ExdIIBt6 explosion-proof and IP56 protection ratings.
---
II. Nitrogen Generator
1. Utilizes hollow fiber membrane separation or PSA (Pressure Swing Adsorption) technology with carbon molecular sieves for nitrogen generation.
2. Entire system has an explosion-proof rating of ExdIIBt6.
3. Protection level: IP56.
---
III. Additional Features
1. Air pre-treatment utilizes a heatless regeneration unit with an explosion-proof rating of ExdIIBt6 and IP56 protection level.
2. Equipment is suitable for installation in Class I, Division 2, and outdoor environments.
3. System is skid-mounted in two parts.
4. System voltage: 380V, 50Hz. Other supply voltages can be achieved through system transformers.
5. Designed operating temperature range: -17°C to 35°C.
6. Design relative humidity: 32% to 90%.
7. Final system output capacity: 20–600 Nm³/h.
8. Nitrogen output pressure: 0.55 MPa to 1.0 MPa.
9. Nitrogen purity: 95% to 99.99%.
10. Equipment certified by classification societies.